Biot number signifies the ratio of

  • Aconvective resistance in the fluid to conductive resistance in the solid
  • conductive resistance in the solid to convective resistance in the fluid
  • Cinertia force to viscous force in the fluid
  • Dbuoyancy force to viscous force in the fluid

Explanation

Biot number Bi=hLc/k is defined as the ratio of internal conductive resistance within a solid (Lc/(kA)) to the external convective resistance at its surface (1/(hA)) — it determines whether the lumped-capacitance (uniform-temperature) assumption is valid.

Source: GATE ME 2014 (Session 1 / Set-1) (2014)