Two systems are available for compressing 6 m³/hr of ambient air to 10 bar. The first uses a single stage compressor (K1) and the second uses a multistage compressor with inter-stage cooling (K2). Which ONE of the following statements is INCORRECT?
- AK2 will have knockout pots in between the stages
- BDischarge temperature of K1 will be higher than that of K2
- K2 will consume more power than K1
- DCost of K2 will be more than that of K1
Explanation
Multistage compression with intercooling makes the overall compression path closer to isothermal, REDUCING total compression work compared to a single adiabatic stage — so K2 consumes LESS power than K1, not more. This makes statement C the incorrect one; the other three are all true (knockout pots remove condensed moisture after cooling, K1's single-stage adiabatic compression gives a higher discharge temperature, and K2's added equipment increases cost).
Source: GATE CH 2011 (2011)