Chemical Reaction Engineering
Ideal Reactor Design
GATE 2011
Hard
The 5 litre CSTR above is replaced by five 1-litre CSTRs in series (same total volume, same k=0.15 min⁻¹, same feed). The overall conversion (in %) is
- A65
- B67
- 73
- D81
Explanation
τ per reactor=1000/500=2 min. kτ=0.15×2=0.3. (1−X)=1/(1+kτ)⁵=1/(1.3)⁵=1/3.713=0.2693. X=1−0.2693≈0.731≈73%.
Source: GATE CH 2011 (2011)